Back to Top

1
Hi, Guest!
  • RELAY
  • SIPROTEC 7SJ6022 multifunction overcurrent and motor protection relay

SIPROTEC 7SJ6022 Multifunction Overcurrent And Motor Protection Relay

Update Terakhir
:
03 / 11 / 2020
Min. Pembelian
:
1 Unit
Harga
CALL
PT Quinratu Karya Prisma
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail SIPROTEC 7SJ6022 Multifunction Overcurrent And Motor Protection Relay

Feeder protection
• Overcurrent-time protection
• Sensitive ground-fault detection
• Directional sensitive ground-fault detection
• Displacement voltage
• Disk emulation
• Overload protection
• Breaker failure protection
• Negative-sequence protection
• Cold load pickup
• Auto-reclosure
• Trip circuit supervision
Motor protection
• Starting time supervision
• Locked rotor
• Restart inhibit
• Undercurrent monitoring
• Temperature monitoring
Control functions
• Commands for control of a circuit-breaker
• Control via keyboard, DIGSI 4 or SCADA system
Measuring functions
• Operational measured values I, V
• Power measurement P, Q, S, Wp, Wq
• Slavepointer
• Mean values
Monitoring functions
• Fault event logging with time stamp (buffered)
• 8 oscillographic fault records
• Continuous self-monitoring
Communication interfaces
• System interface
– IEC 60870-5-103 protocol
– PROFIBUS-DP
– MODBUS RTU/ASCII
• Front interface for DIGSI 4
Feeder protection
• Overcurrent-time protection
• Sensitive ground-fault detection
• Directional sensitive ground-fault detection
• Displacement voltage
• Disk emulation
• Overload protection
• Breaker failure protection
• Negative-sequence protection
• Cold load pickup
• Auto-reclosure
• Trip circuit supervision
Motor protection
• Starting time supervision
• Locked rotor
• Restart inhibit
• Undercurrent monitoring
• Temperature monitoring
Control functions
• Commands for control of a circuit-breaker
• Control via keyboard, DIGSI 4 or SCADA system
Measuring functions
• Operational measured values I, V
• Power measurement P, Q, S, Wp, Wq
• Slavepointer
• Mean values
Monitoring functions
• Fault event logging with time stamp (buffered)
• 8 oscillographic fault records
• Continuous self-monitoring
Communication interfaces
• System interface
– IEC 60870-5-103 protocol
– PROFIBUS-DP
– MODBUS RTU/ASCII
• Front interface for DIGSI 4
Tampilkan Lebih Banyak
pt quinratu karya prisma
pt quinratu karya prisma

PT Quinratu Karya Prisma

Anggota PREMIUM 14 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
25 / 09 / 2021
Hubungi Kami

Detail SIPROTEC 7SJ6022 Multifunction Overcurrent And Motor Protection Relay

Feeder protection
• Overcurrent-time protection
• Sensitive ground-fault detection
• Directional sensitive ground-fault detection
• Displacement voltage
• Disk emulation
• Overload protection
• Breaker failure protection
• Negative-sequence protection
• Cold load pickup
• Auto-reclosure
• Trip circuit supervision
Motor protection
• Starting time supervision
• Locked rotor
• Restart inhibit
• Undercurrent monitoring
• Temperature monitoring
Control functions
• Commands for control of a circuit-breaker
• Control via keyboard, DIGSI 4 or SCADA system
Measuring functions
• Operational measured values I, V
• Power measurement P, Q, S, Wp, Wq
• Slavepointer
• Mean values
Monitoring functions
• Fault event logging with time stamp (buffered)
• 8 oscillographic fault records
• Continuous self-monitoring
Communication interfaces
• System interface
– IEC 60870-5-103 protocol
– PROFIBUS-DP
– MODBUS RTU/ASCII
• Front interface for DIGSI 4
Feeder protection
• Overcurrent-time protection
• Sensitive ground-fault detection
• Directional sensitive ground-fault detection
• Displacement voltage
• Disk emulation
• Overload protection
• Breaker failure protection
• Negative-sequence protection
• Cold load pickup
• Auto-reclosure
• Trip circuit supervision
Motor protection
• Starting time supervision
• Locked rotor
• Restart inhibit
• Undercurrent monitoring
• Temperature monitoring
Control functions
• Commands for control of a circuit-breaker
• Control via keyboard, DIGSI 4 or SCADA system
Measuring functions
• Operational measured values I, V
• Power measurement P, Q, S, Wp, Wq
• Slavepointer
• Mean values
Monitoring functions
• Fault event logging with time stamp (buffered)
• 8 oscillographic fault records
• Continuous self-monitoring
Communication interfaces
• System interface
– IEC 60870-5-103 protocol
– PROFIBUS-DP
– MODBUS RTU/ASCII
• Front interface for DIGSI 4
Tampilkan Lebih Banyak
Kontak Kami