Back to Top

1
Hi, Guest!

Siemens Power Meter Simeas 7KG7755-0DA00-0AA1

Update Terakhir
:
20 / 12 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Pt. Anela Electrindo Nusantara
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail Siemens Power Meter Simeas 7KG7755-0DA00-0AA1

Function overview Device type Top-hat rail mounted device Plastic case 96 mm × 96 mm × 100 mm/ 3.78 in. x 3.78 in. x 3.94 in. ( W × H × D) Degree of protection IP20. Input and output circuits 4 inputs for alternating voltage measurements 3 inputs for alternating current measurements up to 10 A continuous 4 optional DC analog outputs freely configurable: - Direct currents: 0 mA to 20 mA, 4 mA to 20 mA and -20 mA to 20 mA - Direct voltages: 0 V to 10 V and -10 V to 10 V Individually programmable binary outputs. Signalization LEDs Automatically monitor the functions of its hardware, software, and firmware components. Communication Ethernet: IEC 61850 or MODBUS TCP communication protocol Optional serial RS485 interface that enables the device to communicate via the MODBUS RTU or the IEC 60870-5-103 communication protocol- Measurands The following measurands can be recorded or calculated from the measured quantities: TRMS ( True RMS) for alternating voltage and current Active, reactive and apparent power Active, reactive and apparent energy Power frequency Phase angle Power factor and active power factor Voltage and current unbalance - Mean value of the 3 phase voltages: Vavg - Mean value of the 3 phase currents: Iavg.. Time synchronization For a common time basis when communicating with peripheral devices and time stamping of the process data. External time synchronization via Ethernet NTP External time synchronization via field bus using the MODBUS RTU or the IEC 60870-5-103 communication protocol Internal time synchronization via RTC ( if external time synchronization is not available) . Response time for analog and binary outputs The faster response time of the analog and binary output is a very important feature of SICAM T that enables a reliable reaction of the controlling applications. The response time of the device is 120 ms at 50 Hz and 100 ms at 60 Hz.
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Siemens Power Meter Simeas 7KG7755-0DA00-0AA1

Function overview Device type Top-hat rail mounted device Plastic case 96 mm × 96 mm × 100 mm/ 3.78 in. x 3.78 in. x 3.94 in. ( W × H × D) Degree of protection IP20. Input and output circuits 4 inputs for alternating voltage measurements 3 inputs for alternating current measurements up to 10 A continuous 4 optional DC analog outputs freely configurable: - Direct currents: 0 mA to 20 mA, 4 mA to 20 mA and -20 mA to 20 mA - Direct voltages: 0 V to 10 V and -10 V to 10 V Individually programmable binary outputs. Signalization LEDs Automatically monitor the functions of its hardware, software, and firmware components. Communication Ethernet: IEC 61850 or MODBUS TCP communication protocol Optional serial RS485 interface that enables the device to communicate via the MODBUS RTU or the IEC 60870-5-103 communication protocol- Measurands The following measurands can be recorded or calculated from the measured quantities: TRMS ( True RMS) for alternating voltage and current Active, reactive and apparent power Active, reactive and apparent energy Power frequency Phase angle Power factor and active power factor Voltage and current unbalance - Mean value of the 3 phase voltages: Vavg - Mean value of the 3 phase currents: Iavg.. Time synchronization For a common time basis when communicating with peripheral devices and time stamping of the process data. External time synchronization via Ethernet NTP External time synchronization via field bus using the MODBUS RTU or the IEC 60870-5-103 communication protocol Internal time synchronization via RTC ( if external time synchronization is not available) . Response time for analog and binary outputs The faster response time of the analog and binary output is a very important feature of SICAM T that enables a reliable reaction of the controlling applications. The response time of the device is 120 ms at 50 Hz and 100 ms at 60 Hz.
Tampilkan Lebih Banyak
Kontak Kami  
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !