  • Siemens 7SD5225-5AB29-2C20-Z

Siemens 7SD5225-5AB29-2C20-Z

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Lusin
Harga
CALL
Pt. Anela Electrindo Nusantara
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail Siemens 7SD5225-5AB29-2C20-Z

The 7SD52/ 53 relay provides full scheme differential protection and incorporates all functions usually required for the protection of power lines. It is designed for all power and distribution levels and protects lines with two up to six line ends. The relay is designed to provide high-speed and phase-selective fault clearance. The relay uses fiber-optic cables or digital communication networks to exchange telegrams and includes special features for the use in multiplexed communication networks. Also pilot wires connections can be used with an external converter. This contributes toward improved reliability and availability of the electrical power system. The relay is suitable for single and three-phase tripping applications for two up to six line ends. Also, transformers and compensation coils within the differential protection zone are protected as are serial and parallel-compensated lines and cables. The relays may be employed with any type of system grounding. The relay also provides a full-scheme and non-switched distance protection as an optional main 2 protection. Several teleprotection schemes ensure maximum selectivity and high-speed tripping time. The units measure the delay time in the communication networks and adaptively match their measurements accordingly. A special GPS-option allows the use of the relays in communication networks, where the delay time in the transmit and receive path may be quite different. The 7SD52/ 53 has the following features: 2 full-scheme main protections in one unit ( differential and distance protection) High-speed tripping 10 – 15 ms The serial protection interfaces ( R2R interfaces) of the relays can flexibly be adapted to the requirements of all communication media available. If the communication method is changed, fl exible retrofitting of communication modules to the existing confi guration is possible. Tolerates loss of one data connection in a ring topology ( routing in 120 ms) . The differential protection scheme is fully available in a chain topology. Tolerates loss of one data connection in a ring topology ( routing in 120 ms) . The differential protection scheme is fully available in a chain topology. Browser-based commissioning tool. Fault locator for one and two terminal measurement for high accuracy on long lines with high load and high fault resistance. Capacitive charge current compensation increases the sensitivity of the differential protection on cables and long lines.
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Siemens 7SD5225-5AB29-2C20-Z

The 7SD52/ 53 relay provides full scheme differential protection and incorporates all functions usually required for the protection of power lines. It is designed for all power and distribution levels and protects lines with two up to six line ends. The relay is designed to provide high-speed and phase-selective fault clearance. The relay uses fiber-optic cables or digital communication networks to exchange telegrams and includes special features for the use in multiplexed communication networks. Also pilot wires connections can be used with an external converter. This contributes toward improved reliability and availability of the electrical power system. The relay is suitable for single and three-phase tripping applications for two up to six line ends. Also, transformers and compensation coils within the differential protection zone are protected as are serial and parallel-compensated lines and cables. The relays may be employed with any type of system grounding. The relay also provides a full-scheme and non-switched distance protection as an optional main 2 protection. Several teleprotection schemes ensure maximum selectivity and high-speed tripping time. The units measure the delay time in the communication networks and adaptively match their measurements accordingly. A special GPS-option allows the use of the relays in communication networks, where the delay time in the transmit and receive path may be quite different. The 7SD52/ 53 has the following features: 2 full-scheme main protections in one unit ( differential and distance protection) High-speed tripping 10 – 15 ms The serial protection interfaces ( R2R interfaces) of the relays can flexibly be adapted to the requirements of all communication media available. If the communication method is changed, fl exible retrofitting of communication modules to the existing confi guration is possible. Tolerates loss of one data connection in a ring topology ( routing in 120 ms) . The differential protection scheme is fully available in a chain topology. Tolerates loss of one data connection in a ring topology ( routing in 120 ms) . The differential protection scheme is fully available in a chain topology. Browser-based commissioning tool. Fault locator for one and two terminal measurement for high accuracy on long lines with high load and high fault resistance. Capacitive charge current compensation increases the sensitivity of the differential protection on cables and long lines.
Tampilkan Lebih Banyak
Kontak Kami