PowerMonic Power Quality & Disturbance Analysers SPECIFICATIONS PM20 POWER QUALITY ANALYSER • Tables & graphs of 3 phase V, A, pf, f, kW, kVA, kVAr, THD, total energy & tariffs • Log Max/ Min volts and current over log interval • High speed RMS capture for logging ' events' such as fast motor starts and HVAC loads • PQ disturbance capture using " out-of-bounds" absolute limits or percentage change of V& I • Download files while logging - directly or remotely by cellular modem • Auto scaling graphs plus zoom, table summaries with filters, sag/ swell start and stop times • Export all data to csv format, PQ anlaysis and printing of graphs/ reports with notes • Flash memory firmware, Field ( software) upgradeable to PM30 if required later • Waveform event capture ( 120ms of sinewave) with added transient trigger to record sub cycle waveform disturbances. e.g. spikes, switching capacitor banks, harmonic ripple etc. • Individual harmonics up to 48th ( V and I across all phases) • Relative Harmonic Phase Angle PM30 POWER QUALITY ANALYSER - ALL PM20 FEATURES PLUS: • A range of clip on Current Transformers ( CTs) in varying sizes, covering 0 - 3000A, class 0.5M to 2M and IP65 versions. • Flexible CT kits and solutions • Substation Converter Kit: 1A: 200mA ( CK1) or 5A: 200mA ( CK5) • Delta, Star or Isolated voltage lead sets, attachments include large conductor clamps, tinned end leads, 4mm banana plug ends and small alligator clamps • Protective rubber holster and installation strap • External cellular modem kit • Carry Bag ACCESSORIES A typical voltage and current profile A typical voltage & current waveform capture Voltage Current Channels 3 ( isolated) 4 ( 3 Phase + Neutral) Range ( RMS) Low: 63 to 260V P-N 0-3000A High: 125 to 440V P-N Mains voltage ( Phase-Neutral) Any within Range Instrument Accuracy + / - 0.4% + 1 lsd + / - 0.4% + 1 lsd System Accuracy + / - 0.4% + 1 lsd + / - 0.4% + 1 lsd ( class 0.5M CTs) Display Resolution 0.1V 0.1A ( to 500) , 1A ( > 500A) Temperature -100 to + 60 degrees celcius Humidity 20 to 99% RH Protection Class IP65 Sample Rate 11, 413 samples per second Log interval RMS Profile: 10 sec to 4hr log interval RMS Events: 13.6 sec duration at 10ms intervals Waveform Events: 120ms of sinewave at 88us samples ( PM30 only) Power Source Phase A voltage channel ( separately powered upon request) Rechargeable battery for backup and recording during short term interruptions Power Consumption 10 Watts typical Burden 2.2 Ohm Memory 4Mbyte Communication RS232, 1200-115, 200 bps, software selectable Display Selectable scroll of date, time, V, I, pf, f, log status Software PowerView, WindowsTM based Dimensions 230mm ( I ) x 120mm ( w) x 90mm ( d) [ 9" x 4.7" x 3.5" ] Weight 2.5kg or 5.5lbs ( instrument) , typical system 6kg or 13.2lbs Safety Compliance IEC 61010, CAT III
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Power Quality & Disturbance Analysers CHK PM 30

PowerMonic Power Quality & Disturbance Analysers SPECIFICATIONS PM20 POWER QUALITY ANALYSER • Tables & graphs of 3 phase V, A, pf, f, kW, kVA, kVAr, THD, total energy & tariffs • Log Max/ Min volts and current over log interval • High speed RMS capture for logging ' events' such as fast motor starts and HVAC loads • PQ disturbance capture using " out-of-bounds" absolute limits or percentage change of V& I • Download files while logging - directly or remotely by cellular modem • Auto scaling graphs plus zoom, table summaries with filters, sag/ swell start and stop times • Export all data to csv format, PQ anlaysis and printing of graphs/ reports with notes • Flash memory firmware, Field ( software) upgradeable to PM30 if required later • Waveform event capture ( 120ms of sinewave) with added transient trigger to record sub cycle waveform disturbances. e.g. spikes, switching capacitor banks, harmonic ripple etc. • Individual harmonics up to 48th ( V and I across all phases) • Relative Harmonic Phase Angle PM30 POWER QUALITY ANALYSER - ALL PM20 FEATURES PLUS: • A range of clip on Current Transformers ( CTs) in varying sizes, covering 0 - 3000A, class 0.5M to 2M and IP65 versions. • Flexible CT kits and solutions • Substation Converter Kit: 1A: 200mA ( CK1) or 5A: 200mA ( CK5) • Delta, Star or Isolated voltage lead sets, attachments include large conductor clamps, tinned end leads, 4mm banana plug ends and small alligator clamps • Protective rubber holster and installation strap • External cellular modem kit • Carry Bag ACCESSORIES A typical voltage and current profile A typical voltage & current waveform capture Voltage Current Channels 3 ( isolated) 4 ( 3 Phase + Neutral) Range ( RMS) Low: 63 to 260V P-N 0-3000A High: 125 to 440V P-N Mains voltage ( Phase-Neutral) Any within Range Instrument Accuracy + / - 0.4% + 1 lsd + / - 0.4% + 1 lsd System Accuracy + / - 0.4% + 1 lsd + / - 0.4% + 1 lsd ( class 0.5M CTs) Display Resolution 0.1V 0.1A ( to 500) , 1A ( > 500A) Temperature -100 to + 60 degrees celcius Humidity 20 to 99% RH Protection Class IP65 Sample Rate 11, 413 samples per second Log interval RMS Profile: 10 sec to 4hr log interval RMS Events: 13.6 sec duration at 10ms intervals Waveform Events: 120ms of sinewave at 88us samples ( PM30 only) Power Source Phase A voltage channel ( separately powered upon request) Rechargeable battery for backup and recording during short term interruptions Power Consumption 10 Watts typical Burden 2.2 Ohm Memory 4Mbyte Communication RS232, 1200-115, 200 bps, software selectable Display Selectable scroll of date, time, V, I, pf, f, log status Software PowerView, WindowsTM based Dimensions 230mm ( I ) x 120mm ( w) x 90mm ( d) [ 9" x 4.7" x 3.5" ] Weight 2.5kg or 5.5lbs ( instrument) , typical system 6kg or 13.2lbs Safety Compliance IEC 61010, CAT III