Pepperl+Fuchs KFD-SL2-EX2

Update Terakhir
:
06 / 02 / 2021
Min. Pembelian
:
1 Unit
Harga
CALL
Pt. Anela Electrindo Nusantara
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail Pepperl+Fuchs KFD-SL2-EX2

Solenoid Driver Zone 2 Div. 2 Zone 0, 1, 2 Div. 1, 2 KFD2-SL2-Ex2 2- 3- 1+ 5- 6- 4+ 24 V DC 14+ 15- Power Rail ERR 24 V DC I II 7 8 (+/-) 9 I II V Connection Assembly • 2-channel isolated barrier • 24 V DC supply (Power Rail) • Output 45 mA at 11.7 V DC • Logic input, non-polarized • Lead monitoring • Up to SIL2 acc. to IEC 61508 Function This isolated barrier is used for intrinsic safety applications. It supplies power to solenoids, LEDs, and audible alarms, located in a hazardous area. It is controlled via a logic signal. The input has two defined states: 1-Signal = 16 V DC ... 30 V DC, 0- Signal = 0 V DC ... 5 V DC. The current consumption of the input is about 3 mA. At full load, 11.7 V at 45 mA is available for the hazardous area application. If the field impedance is > 10 kΩ for lead breakage or < 50 Ω for short circuits a line fault is detected. A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output. 2 Features

Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Pepperl+Fuchs KFD-SL2-EX2

Solenoid Driver Zone 2 Div. 2 Zone 0, 1, 2 Div. 1, 2 KFD2-SL2-Ex2 2- 3- 1+ 5- 6- 4+ 24 V DC 14+ 15- Power Rail ERR 24 V DC I II 7 8 (+/-) 9 I II V Connection Assembly • 2-channel isolated barrier • 24 V DC supply (Power Rail) • Output 45 mA at 11.7 V DC • Logic input, non-polarized • Lead monitoring • Up to SIL2 acc. to IEC 61508 Function This isolated barrier is used for intrinsic safety applications. It supplies power to solenoids, LEDs, and audible alarms, located in a hazardous area. It is controlled via a logic signal. The input has two defined states: 1-Signal = 16 V DC ... 30 V DC, 0- Signal = 0 V DC ... 5 V DC. The current consumption of the input is about 3 mA. At full load, 11.7 V at 45 mA is available for the hazardous area application. If the field impedance is > 10 kΩ for lead breakage or < 50 Ω for short circuits a line fault is detected. A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output. 2 Features