Back to Top

1
Hi, Guest!
  • RELAY
  • Overcurrent Protection 7SJ8042-5EB00-1FB0/CC Siemens

Overcurrent Protection 7SJ8042-5EB00-1FB0/CC Siemens

Update Terakhir
:
09 / 02 / 2021
Min. Pembelian
:
1 Unit
Harga
CALL
Pt. Anela Electrindo Nusantara
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail Overcurrent Protection 7SJ8042-5EB00-1FB0/CC Siemens

Protection functions Time-overcurrent protection ( 50, 50N, 51, 51N) Directional time-overcurrent protection ( 67, 67N) Sensitive dir./ non-dir. ground-fault detection ( 67Ns, 50Ns) Displacement voltage ( 64) High-impedance restricted ground fault ( 87N) Inrush restraint Undercurrent monitoring ( 37) Overload protection ( 49) Under-/ overvoltage protection ( 27/ 59) Under-/ overfrequency protection ( 81O/ U) Breaker failure protection ( 50BF) Phase unbalance or negative-sequence protection ( 46) Phase-sequence monitoring ( 47) Synch-check ( 25) Auto-reclosure ( 79) Fault locator ( 21FL) Lockout ( 86) Control functions/ programmable logic Commands for the ctrl. of CB, disconnect switches ( isolators/ isolating switches) Control through keyboard, binary inputs, DIGSI 4 or SCADA system User-defined PLC logic with CFC ( e.g. interlocking) Monitoring functions Operational measured values V, I, f Energy metering valuesWp, Wq Circuit-breaker wear monitoring Minimum and maximum values Trip circuit supervision ( 74TC) Fuse failure monitor 8 oscillographic fault records Communication interfaces System/ service interface – IEC 61850 – IEC 60870-5-103 – PROFIBUS-DP – DNP 3.0 – MODBUS RTU Ethernet interface for DIGSI 4 USB front interface for DIGSI 4 Hardware 4 current transformers 0/ 3 voltage transformers 3/ 7 binary inputs ( thresholds configurable using software) 5/ 8 binary outputs ( 2 changeover/ Form C contacts) 1 live-status contact Pluggable current and voltage terminals
safety relay
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Overcurrent Protection 7SJ8042-5EB00-1FB0/CC Siemens

Protection functions Time-overcurrent protection ( 50, 50N, 51, 51N) Directional time-overcurrent protection ( 67, 67N) Sensitive dir./ non-dir. ground-fault detection ( 67Ns, 50Ns) Displacement voltage ( 64) High-impedance restricted ground fault ( 87N) Inrush restraint Undercurrent monitoring ( 37) Overload protection ( 49) Under-/ overvoltage protection ( 27/ 59) Under-/ overfrequency protection ( 81O/ U) Breaker failure protection ( 50BF) Phase unbalance or negative-sequence protection ( 46) Phase-sequence monitoring ( 47) Synch-check ( 25) Auto-reclosure ( 79) Fault locator ( 21FL) Lockout ( 86) Control functions/ programmable logic Commands for the ctrl. of CB, disconnect switches ( isolators/ isolating switches) Control through keyboard, binary inputs, DIGSI 4 or SCADA system User-defined PLC logic with CFC ( e.g. interlocking) Monitoring functions Operational measured values V, I, f Energy metering valuesWp, Wq Circuit-breaker wear monitoring Minimum and maximum values Trip circuit supervision ( 74TC) Fuse failure monitor 8 oscillographic fault records Communication interfaces System/ service interface – IEC 61850 – IEC 60870-5-103 – PROFIBUS-DP – DNP 3.0 – MODBUS RTU Ethernet interface for DIGSI 4 USB front interface for DIGSI 4 Hardware 4 current transformers 0/ 3 voltage transformers 3/ 7 binary inputs ( thresholds configurable using software) 5/ 8 binary outputs ( 2 changeover/ Form C contacts) 1 live-status contact Pluggable current and voltage terminals
safety relay
Tampilkan Lebih Banyak
Kontak Kami