NEUTRAL GROUDING RESISTORS ( NGR)

Update Terakhir
:
13 / 06 / 2020
Min. Pembelian
:
1 Unit
Harga
CALL
PT Quinratu Karya Prisma
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail NEUTRAL GROUDING RESISTORS ( NGR)

Neutral Grounding Resistors are used for resistance grounding of industrial power system. They are generally connected between ground and neutral of transformers, generators and grounding transformers. Neutral Grounding Resistors are used in order to limit maximum fault current to a value which will not damage the equipment in the power system, yet allow sufficient flow of fault current to operate protective relays to clear the fault. Although it is possible to limit fault currents with high resistance Neutral Grounding Resistors, earth short circuit currents can be extremely reduced. As a result of this fact, protection devices may not sense the fault. Therefore, it is the most common application to limit single phase fault currents with low resistance Neutral Grounding Resistors to approximately rated current of transformer and / or generator.
resistor
Tampilkan Lebih Banyak
pt quinratu karya prisma
pt quinratu karya prisma

PT Quinratu Karya Prisma

Anggota PREMIUM 14 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
25 / 09 / 2021
Hubungi Kami

Detail NEUTRAL GROUDING RESISTORS ( NGR)

Neutral Grounding Resistors are used for resistance grounding of industrial power system. They are generally connected between ground and neutral of transformers, generators and grounding transformers. Neutral Grounding Resistors are used in order to limit maximum fault current to a value which will not damage the equipment in the power system, yet allow sufficient flow of fault current to operate protective relays to clear the fault. Although it is possible to limit fault currents with high resistance Neutral Grounding Resistors, earth short circuit currents can be extremely reduced. As a result of this fact, protection devices may not sense the fault. Therefore, it is the most common application to limit single phase fault currents with low resistance Neutral Grounding Resistors to approximately rated current of transformer and / or generator.
resistor
Tampilkan Lebih Banyak
Kontak Kami