Detail MULTILIN LM 10 Motor Ptrotection System GENERAL ELECTRIC

Summary • Affected products: LM10 Motor Protection System • Date of release: February 20, 2006 • Firmware revision: 1.50 • EnerVista LM10 Setup revision: 2.30 • Manual revision: GEK-106642B Release summary This release note covers the LM10 Motor Protection System version 1.50 release. This release has modified the DeviceNet polling function by allowing one of three possible data groups to be read, based on the value of the Poll Data setting. In the previous revision, DeviceNet polling returned seven bytes of data. Version 1.50 has also added an undervoltage/ overvoltage setting, allowing the user to disable this feature. In previous revisions, this feature was always enabled. The maximum delay time for the Run1-Run2 and Run2-Run1 timers has also been extended from “ 0 to 180 seconds” to “ 0 to 600 seconds” .
testing instrument
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail MULTILIN LM 10 Motor Ptrotection System GENERAL ELECTRIC

Summary • Affected products: LM10 Motor Protection System • Date of release: February 20, 2006 • Firmware revision: 1.50 • EnerVista LM10 Setup revision: 2.30 • Manual revision: GEK-106642B Release summary This release note covers the LM10 Motor Protection System version 1.50 release. This release has modified the DeviceNet polling function by allowing one of three possible data groups to be read, based on the value of the Poll Data setting. In the previous revision, DeviceNet polling returned seven bytes of data. Version 1.50 has also added an undervoltage/ overvoltage setting, allowing the user to disable this feature. In previous revisions, this feature was always enabled. The maximum delay time for the Run1-Run2 and Run2-Run1 timers has also been extended from “ 0 to 180 seconds” to “ 0 to 600 seconds” .
testing instrument
Tampilkan Lebih Banyak
Kontak Kami