Detail Dowin YD30KO85EH DIN Rail Mounted DC Surge Protection

Main Technical Data Electrical Performance Tested To IEC 61643-1 Arrester Class Class II, Type 2 Number Of Ports Single port device Technology MOV Nominal Operating Voltage Un 48 Vdc Maximum Continuous Operating Voltage Uc 85 Vdc Nominal Discharge Current In ( 8x20¼ s) 15 kA Maximum Discharge Current Imax ( 8x20¼ s) 30 kA Voltage Protection Level Up ( 5 Ka, 8x20¼ s) V+ to V- d 300 V V- to PE d 150 V Leakage Current To PE At Un 10 ¼ A Recommended Over-Current Protection 32 A circuit breaker with C tripping characteristic ( per IEC 60364-4-43) Response Time < 25 ns Status Indication LED; Green = Normal, Red = replace 2 pin contact switch; closed circuit = normal, open = replace Maximum Contact Switch Rating 250 Vac / 3 A
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Dowin YD30KO85EH DIN Rail Mounted DC Surge Protection

Main Technical Data Electrical Performance Tested To IEC 61643-1 Arrester Class Class II, Type 2 Number Of Ports Single port device Technology MOV Nominal Operating Voltage Un 48 Vdc Maximum Continuous Operating Voltage Uc 85 Vdc Nominal Discharge Current In ( 8x20¼ s) 15 kA Maximum Discharge Current Imax ( 8x20¼ s) 30 kA Voltage Protection Level Up ( 5 Ka, 8x20¼ s) V+ to V- d 300 V V- to PE d 150 V Leakage Current To PE At Un 10 ¼ A Recommended Over-Current Protection 32 A circuit breaker with C tripping characteristic ( per IEC 60364-4-43) Response Time < 25 ns Status Indication LED; Green = Normal, Red = replace 2 pin contact switch; closed circuit = normal, open = replace Maximum Contact Switch Rating 250 Vac / 3 A