Back to Top

1
Hi, Guest!
  • RELAY
  • Directional Earth-Fault Relay SPAS 120 C ABB

Directional Earth-Fault Relay SPAS 120 C ABB

Update Terakhir
:
16 / 12 / 2019
Min. Pembelian
:
1 Lusin
Harga
CALL
Pt. Anela Electrindo Nusantara
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail Directional Earth-Fault Relay SPAS 120 C ABB

Two-stage directional earth-fault relay for distribution networks Directional low-set earth-fault stage with definite time characteristic Directional high-set earth-fault stage with instantaneous operation or definite time characteristic The operation direction of the high-set earthfault stage can be the same as that of the low-set stage or the opposite Output relay functions can be freely configured by the user Flexible adaptation of the relay to different applications Manual selection or remote control of the operation characteristic I0sinj or I0cosj Digital display of settings, measured quantities, recorded fault values, etc Extensive two-way data communication via fibre- optic serial bus Continuous self-supervision of hardware and software including autodiagnosis Powerful software support for parametrization and supervision of the relay Member of the SPACOM product family and PYRAMID® , ABB' s coordinated protection and control concept
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Directional Earth-Fault Relay SPAS 120 C ABB

Two-stage directional earth-fault relay for distribution networks Directional low-set earth-fault stage with definite time characteristic Directional high-set earth-fault stage with instantaneous operation or definite time characteristic The operation direction of the high-set earthfault stage can be the same as that of the low-set stage or the opposite Output relay functions can be freely configured by the user Flexible adaptation of the relay to different applications Manual selection or remote control of the operation characteristic I0sinj or I0cosj Digital display of settings, measured quantities, recorded fault values, etc Extensive two-way data communication via fibre- optic serial bus Continuous self-supervision of hardware and software including autodiagnosis Powerful software support for parametrization and supervision of the relay Member of the SPACOM product family and PYRAMID® , ABB' s coordinated protection and control concept
Tampilkan Lebih Banyak
Kontak Kami