Back to Top

1
Hi, Guest!
  • RELAY
  • Buchholz Relay COMEM type NF 80

Buchholz Relay COMEM Type NF 80

Update Terakhir
:
16 / 12 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Pt. Anela Electrindo Nusantara
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail Buchholz Relay COMEM Type NF 80

The following protective devices are used so that, upon a fault development inside a Transformer, an alarm is set off or the Transformer is disconnected from the circuit. In the event of a fault, oil or insulations decomposes by heat, producing gas or developing an impulse oil flow. To detect these phenomena, a Buchholz relay is installed. Buchholz Relay The Buchholz relay is installed at the middle of the connection pipe between the Transformer tank and the conservator. There are a 1st stage contact and a 2nd stage contact as shown in Fig. ( 28) . the 1st stage contact is used to detect minor faults. When gas produced in the tank due to a minor fault surfaces to accumulate in the relay chamber within a certain amount ( 0.3Q-0.35Q) or above, the float lowers and closes the contact, thereby actuating the alarm device.
Tampilkan Lebih Banyak
pt. aneka electrindo nusantara
pt. aneka electrindo nusantara

PT. ANEKA ELECTRINDO NUSANTARA

Anggota PREMIUM 13 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
-
Hubungi Kami

Detail Buchholz Relay COMEM Type NF 80

The following protective devices are used so that, upon a fault development inside a Transformer, an alarm is set off or the Transformer is disconnected from the circuit. In the event of a fault, oil or insulations decomposes by heat, producing gas or developing an impulse oil flow. To detect these phenomena, a Buchholz relay is installed. Buchholz Relay The Buchholz relay is installed at the middle of the connection pipe between the Transformer tank and the conservator. There are a 1st stage contact and a 2nd stage contact as shown in Fig. ( 28) . the 1st stage contact is used to detect minor faults. When gas produced in the tank due to a minor fault surfaces to accumulate in the relay chamber within a certain amount ( 0.3Q-0.35Q) or above, the float lowers and closes the contact, thereby actuating the alarm device.
Tampilkan Lebih Banyak
Kontak Kami