Back to Top

1
Hi, Guest!
  • 1B230 Auto Reclose Relay " RMS"

1B230 Auto Reclose Relay RMS

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Harga
CALL
PT Quinratu Karya Prisma
 
Merupakan perusahaan yang berkonsentrasi dalam bidang electrikal, baik untuk penyediaan material part maupun untuk sarvice, maintenance dan perencanaan electrician untuk industri building dan lain lain. Sesuai dengan moto perusahaan kamu "WE ARE SOLUTION FOR ELECTRICAL"
Kami hadir sebagai perusahaan

Detail 1B230 Auto Reclose Relay RMS

Operating records for overhead power lines reveal that most faults are of a transient nature ( e.g. lightning induced) & that service interruptions may be minimized by use of automatic reclosing of circuit breakers. An automatic reclosure of the circuit breaker, after the fault clears, provides improved service continuity & system stability. The 1B230 Series Reclose Relay provides for single or double shot automatic reclosing of circuit breakers, following interruption of supply due to a fault in the system. Features * Single or double shot reclose with selectable auto reset mode * Shunt initiate input * Optional series initiate input * Safe to reclose input * Line voltage interlock * CB reclose spring status input to defer auto reclose pulse until fully charged * Lockout LED indication * Drive to lockout input * Remote reset input * Reclose in progress LED * Instantaneous protection inhibit output & LED indication * Wide auxiliary supply range with fail alarm contact * Independently adjustable dead time delay per shot * Common adjustable reclaim time delay * Optional reclose counter * Simple rugged design * Size 4M draw out case
Tampilkan Lebih Banyak
pt quinratu karya prisma
pt quinratu karya prisma

PT Quinratu Karya Prisma

Anggota PREMIUM 14 Tahun
Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id, Bekasi
Indonesia Komplek dosen IKIP Blok 2. No.43,Jati BeningEmail : marketing@aen.co.id
Bekasi
18 / 09 / 2021
Hubungi Kami

Detail 1B230 Auto Reclose Relay RMS

Operating records for overhead power lines reveal that most faults are of a transient nature ( e.g. lightning induced) & that service interruptions may be minimized by use of automatic reclosing of circuit breakers. An automatic reclosure of the circuit breaker, after the fault clears, provides improved service continuity & system stability. The 1B230 Series Reclose Relay provides for single or double shot automatic reclosing of circuit breakers, following interruption of supply due to a fault in the system. Features * Single or double shot reclose with selectable auto reset mode * Shunt initiate input * Optional series initiate input * Safe to reclose input * Line voltage interlock * CB reclose spring status input to defer auto reclose pulse until fully charged * Lockout LED indication * Drive to lockout input * Remote reset input * Reclose in progress LED * Instantaneous protection inhibit output & LED indication * Wide auxiliary supply range with fail alarm contact * Independently adjustable dead time delay per shot * Common adjustable reclaim time delay * Optional reclose counter * Simple rugged design * Size 4M draw out case
Tampilkan Lebih Banyak
Kontak Kami